Rockford Industrial Area Revival Project - Moderated newsgroup   >   Metalworking Machining and CNC   >   Rockford   >   Airport Area   >   Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100

Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100


Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100


From: Katina Love
Subject Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100
HP/Agilent 8714C Network Analyzer, RF, 300 kHz to 3.0GHz - With Original User's Guide, Programming Guide, HP BASIC Guide, and Service Guide.
* Integrated transmission/reflection test set with narrowband and broadband detection
* "Real time" sweep speed (50 ms/sweep), synthesized 1 Hz resolution source, and 100 dB of system dynamic range
* Internal 3.5-inch disk drive (LIF/DOS formats) and VGA interface
* Internal Agilent Instrument BASIC (IBASIC) capability (opt 1C2 With a $1,000 value)
* 60dB Attenuator (opt 1E2 with a $1,000 value)
* Fault location/SRL (opt 100 with a $1,500 value)
Number of display measurements
Two simultaneous measurements available
• Narrowband: reflection (A/R), transmission (B/R), A, B, R
• Broadband: X, Y, Y/X, X/Y, Y/R*, power (B*, R*), conversion loss (B*/R*)
• Rectilinear: log or linear magnitude, SWR
• Phase, group delay, real and imaginary, Smith chart, and polar.
Each display channel has eight markers. Markers are coupled between channels. Any one of eight markers can be the reference marker for delta marker operation. Annotation for up to four markers can be displayed at one time.
Markers can be used for various functions: marker search, mkr to max, mkr to min, mkr ® target, mkr bandwidth, mkr delta frequency, mkr delta amplitude, and notch. Also with user-defined target values, mkr ® center, mkr ® reference, mkr ® electrical delay are available. The tracking function enables continuous update of marker search values on each sweep.
For testing cable TV broadband amplifiers, the slope and flatness functions enable rapid tuning. Marker statistics enable measurement of the mean, peak-to-peak, and standard deviation of the data between two markers.
380 Kbytes of nonvolatile storage is available to store up to 20 instrument states via the save/recall menu. Instrument states can include all control settings, active limit lines, memory trace data, active calibration coefficients, and custom display titles.
Data, instrument states (including calibration data), and IBASIC programs can also be stored on disk, using the built-in disk drive. Data can be stored to disk in MS-DOS (R) format. Data can be stored in binary, PCX, HP-GL, or ASCII formats.
Hard copy plots are automatically produced with HP-GL compatible digital plotters such as the HP 7475A. Hardcopy prints can be dumped to compatible graphics printers such as the HP DeskJet or LaserJet (in single color or multicolor format).
The analyzer provides Centronics, RS-232C, GPIB, and LAN interfaces.
Printouts of instrument data are directly produced with a printer such as any HP DeskJet or LaserJet.
Single-channel, dual-channel overlay (both traces on one graticule), or dual-channel split (each trace on separate graticules).
Display current measurement data, memory data, or current measurement with memory data simultaneously. Vector division of current linear measurement values and memory data.
Start/stop, center/span, or CW frequency, scale/division, reference level, marker data, soft key functions, warning and caution messages, titles, clock, and pass/fail indication.
Create test limit lines that appear on the display for pass/fail testing. Limits may be any combination of lines or discrete points. Limit test TTL output available for external control or indication.
Limit lines are only available in rectilinear formats.
GPIB interface operates to IEEE 488.2 and SCPI standard interface commands.
Allows the analyzer to request control of the GPIB (when an active controller is present) output to a plotter or printer.
Lets the analyzer become the controller on the GPIB bus to directly control a plotter or a printer.
This option adds a built-in 60 dB step attenuator, extending the source output power low-end range to –60 dBm.
This option adds a resident IBASIC system controller, facilitating automated measurements, and control of other devices. Using keystroke recording for the simplest applications, or an optional keyboard to write complex control and calculation programs, IBASIC improves productivity by customizing your measurements.
Fault location and structural return loss software (Option 100)
All Items sell with 5 days right of return, and 15 days GUARANTEE on all parts and labor.
If in order to comply with our guarantee, we need to refund your money, you will get a FULL refund for the price of the unit...
If you need to make use of the 15 days Guarantee - We will fix, or replace, your unit. In case every attempt to fix or replace it fails, we’ll refund your money.
Be sure to add me to your favorites list!
Contact: katina_love@rockford-industrial.com (Katina Love)




Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100 Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100 Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100 Hp 8714C network analyzer, 300 khz-3.0 ghz 1C2/1E1/100