Rockford Industrial Area Revival Project - Moderated newsgroup   >   Presses   >   Rockford   >   Industrial Park   >   Fluke victoreen 470A panoramic radiation survery meter

Fluke victoreen 470A panoramic radiation survery meter


Fluke victoreen 470A panoramic radiation survery meter


From: Clyde Curtis
Subject Fluke victoreen 470A panoramic radiation survery meter
___________________________________________________________________________________
The 470A is unparalleled in health physics surveys instrumentation. The latest solid-state IC technology has been utilized to miniaturize circuitry, reduce weight and increase reliability. Accuracy and convenience have also been carefully considered to assure the best possible indication of true radiation exposure. An extremely rugged high impact molded plastic case provides easy decontamination.
The 470A is ideal in numerous applications including:
• General health physics surveys
Surveying nuclear power plants
Monitoring x-ray and radiotherapy facilities
0-3, 10, 30, 100, 300, 1000 mR/h and R/h
Integrate: 0-3, 10, 30, 100, 300, 1000 mR
Alpha, beta, gamma and x-ray
Unsealed air ionization chamber
Expanded polystyrene/275 cc vol
Cycolac Equilibrium Sleeve/Cap
3.125 in (7.9 cm) scale, taut band movement
Function Switch (R/h, mR/h, mR integrate)
* Range Switch (Off, Battery Check, 1000, 300, 100, 30, 10, 3)
* High Voltage Check Switch
* Coarse Zero Adjust Potentiometer
* ±15% from 8.0 keV to 300 keV-bare
* ±10% from 40 keV to 2 MeV-Covered
* 1.5 sec on 100 mR/h and 300 mR/h range
Less than 8 seconds on Function & Set Zero
Two 1.5 V “D” cells and four 22.5 V No. 505 Eveready
Can be properly adjusted in a radiation field
Temperature Range: -20° to +120°F (-29° to +49°C)
Minimum energy to penetrate chamber: Alpha: 8 MeV
6% per 10°C on 3 mR/h and 3 R/h range
* 2% per 10°C on 10 mR/h and 10 R/h range
* 0.6% per 10°C on 30 mR/h range and 30 R/h range
* Can be completely eliminated by rezeroing
___________________________________________________________________________________
This is used, but in good condition. Of course, if you're going to use this is a sensitive environment, you will want to have it calibrated and certified by a trained professional.
Check out the picture for more information. Feel free to ask any questions. RATHER CALL? Feel free to reach me (Trent), toll free, at (***) 972-1346.
Contact: c-curtis@rockford-industrial.com (Clyde Curtis)




Fluke victoreen 470A panoramic radiation survery meter Fluke victoreen 470A panoramic radiation survery meter Fluke victoreen 470A panoramic radiation survery meter