Rockford Industrial Area Revival Project - Moderated newsgroup   >   Packing and Shipping Supplys   >   Machesney Park   >   Tektronix tds 3TRG trg module TDS3000 dpo oscilloscope

Tektronix tds 3TRG trg module TDS3000 dpo oscilloscope


Tektronix tds 3TRG trg module TDS3000 dpo oscilloscope


From: Bernice Hughes
Subject Tektronix tds 3TRG trg module TDS3000 dpo oscilloscope
Information - Questions? Call (***)-253-6114 Ask for Chip or Trip
When this module is installed in the TDS 3000 Series scope, an advanced trigger menu is added to the scope with the appropriate logic and pulse triggering capability.
* Logic triggering is extremely useful in the troubleshooting of digital circuits. The oscilloscope is triggered when two signals meet a Boolean trigger condition. This module provides pattern and state logic trigger modes.
* Pattern triggering triggers the oscilloscope when two signals become logically true or false. Basically, the pattern-triggering feature triggers the oscilloscope from the output of a two-input AND, OR, NAND or NOR logic gate. You can specify time constraints and signal threshold levels as part of the triggering condition. The trigger is useful for digital logic troubleshooting.
* State triggering triggers the oscilloscope when a state signal is true or false at the time a clock signal transition is true. This trigger is useful for troubleshooting digital logic synchronous state machines.
* Pulse Trigger Features
* Pulse triggering triggers the oscilloscope when a signal meets a timing or threshold condition. The advanced trigger module provides three pulse trigger modes: pulse width, runt pulse and slew rate.
* Pulse Width (or Glitch)
* Pulse Width triggering triggers the oscilloscope when a signal pulse width is less than, greater than, equal to or not equal to a specified pulse width. this trigger is useful for digital logic troubleshooting.
* Runt Pulse triggering triggers the oscilloscope when a signal pulse is less than a specified threshold level. You can also specify runt pulse-width parameters. This trigger is useful for troubleshooting bus-contention problems.
* Slew Rate triggering triggers the oscilloscope when a signal's slew rate (rise or fall time) is less than, greater than, equal to or not equal to a specified slew rate. This trigger is useful for troubleshooting digital bus transceivers, transmission lines and op-amp circuits.
This was designed to work with all versions of the Tektronix TDS3000 and TDS3000B Digital Phosphor Oscilloscopes.
This item is in excellent condition, working perfectly, and comes with a 14 Day Guarantee Against DOA.
Our 14 Day Guarantee Against DOA (Dead On Arrival) does not guarantee compatibility.
Cashier's Check, Company Check, Money Order, and Personal Check
Bank Wire - Contact for Information
Bank Wire - Contact for Information
Contact: B_Hughes@rockford-industrial.com (Bernice Hughes)