New ICM280 goodman furnace control circuit board hvac


New ICM280 goodman furnace control circuit board hvac


From: Shelly Gilliam
Subject New ICM280 goodman furnace control circuit board hvac
ICM280 Goodman Furnace Control Circuit Board HVAC NEW
Controls Gas Valve, Ignitor, Two Speed Blower Motor, Inducer, Humidifier (Both 120v & 24v Input), and Air Cleaner. Replaces OEM Goodman, UTEC and TI Models
* Includes flash code diagnostics.
* Includes mounting hole template.
* Fused to protect low voltage system transformers.
This automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation. This control incorporates system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. It is designed as a replacement for the following controls:
Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage your thermostat and or circuit board.
(All times are in seconds, unless noted otherwise) Timing Specification Description
Pre-Purge Initial delay between thermostat contact closure and trial for ignition 15 seconds
Initial Ignitor Warm-Up Duration of ignitor warm-up time on the first 64 attempts 15 seconds
Retry Ignitor Warm-Up Duration of ignitor warm-up time if the control retries 20 seconds
Ignition Activation Period The period of time between energizing the main gas valve and deactivation of 5 seconds the ignition means prior to the lockout time.
Trial for Ignition Period during which the valve and ignition source is activated, attempting to 7 seconds ignite gas at the burner.
Retries Additional ignition attempts if the original ignition attempt is unsuccessful. 2 times Valve Sequence Period Valve sequence period is the cumulative total amount of time that the gas valve 12 seconds is energized before entering lockout.
Inter-Purge Period between trials for ignition when both the gas valve and ignition source 30 seconds are deactivated to allow unburned gas to escape before the next trial.
Post-Purge After all ignition cycles are complete, the control will enter post-purge. The 25/29 seconds combustion fan will remain on to allow unburned gas to escape. After post-purge (90+ option) is complete, the combustion fan will turn off.
Lockout Time The period of time between initiation of gas flow and the action to shut off the gas 300 seconds flow in the event of failure to establish proof of the supervised ignition source or the supervised main burner flame. Reinitiating the lighting sequence requires a manual operation if ignition is required before Auto reset.
Heat Delay to Fan On Timing to allow the heat to build up in the plenum before turning on the fan. 30 seconds Heat Delay to Fan Off* Timing to allow the fan to run after the call for heat ends. This allows residual heat 90/120/150 seconds to be removed from the heat exchanger and distributed to the conditioned space.
Cool Delay to Fan On Timing to allow the cooling coils to cool off before turning on the fan 5 seconds Cool Delay to Fan Off Timing to allow the fan to run after the call for cool ends. This allows residual 60 seconds cooling capacity to be removed from the cooling coils and distributed to the conditioned space.
Auto Reset If shutoff occurs, the control delays for a specific recycle delay period before 60 minutes beginning another trial for ignition (models with retries only).
Replaces Obsolete Circuit Board Part Numbers:
B180099-10 B18009910 B180099-13 B18009913 1809913S 1809913 VAL1586 VAL01586 B18099-6 1(***)-930 1012933D 1012-933D B18099-06 B18099-08 B18099-10 B18099-13 B18099-13S 41F-5 50T35730 50T35743 B180996 10-451 50T35-743 50T35743 50T35-730 50T35730 B1809913 1012-933D 1012933D 41F-5 41F5 B18099-06 B18099-08 B18099-10 B18099-13 B1809913S 025-18(***)-000 02518149000 1012-83-9336AHSC1 50T35-743 18099-13S B18099-10 B1809908 B1809910 B18099-08 B18099-13 BL C14 B18099-13S B18099-06 B1809906 50T35-743 50T35743 50T35-730 B1809913 1012-933D CARB1809913S
Operating Temperature . .-40 to 176F
Humidity Range . . 95% RH (non-condensing)
Mounting . . . Plastic standoffs
Electrical Ratings @ 77F (25C)
Input Voltage . . . 20-30 VAC RMS 50/60 Hz
Maximum Input Current @ 30 VAC 0.35 amp
Valve Relay 1.5 amp @ 30 VAC 50/60 Hz 0.6 pf
Ignitor Relay . . . 5.0 amp @ 120 VAC 50/60 Hz
Inducer Relay . . . 4.0 FLA-8.0 LRA @ 120 VAC
Circulator Relay . . .14.5 FLA-25.0 LRA @ 120 VAC
Minimum current to insure flame detection . . . 75 uA DC
Maximum current for non-detection . . . . . . . . 0.10 uA DC
Maximum allowable leakage resistance . . . . . 100 M ohms
INCLUDED:Wiring Harness Plug and Instructions.
Used in Goodman Janitrol Furnace Models:
GMT070-3B GNP050-3 GDT045-3B GDT045-3B* GDT070-3B GDT070-3B* GDT090-4B GDT090-4B* GDT115-5B GDT115-5B* GMNT040-3B GMNT040-3B* GMNT060-3B GMNT060-3B* GMNT080-4B GMNT080-4B* GMNT100-4B GMNT100-4B* GMNT120-5B GMNT120-5B GMNT120-5D GMNT120-5D GMT045-3B GMT115-5A GMNT045-3B GMT045-3B GMT070-3B GMNT070-3B GMT070-3B* GMT070-4B GMNT070-4B* GMT070-4B* GMT090-3B GMNT090-3B* GMT070-4B* GMT090-4B GMNT090-4B* GMT090-4B* GMT090-5B GMNT090-5B* GMT090-5B* GMT115-5B GMNT115-5B* GMT115-5B* GMT140-5B GMNT140-5B* GMT140-5BB* GMT140-5D GMT140-5D GMTH045-3B GMTH045-3B* GMTH070-4B GMTH070-4B* GMTH090-5B GMTH090-5B* GHPN060-3 GMT045-3 GMT070-3 GMT070-4 GMT090-3 GMT090-4 GMT090-5 GMT115-5 GMT135-5 GMT140-5 GDT045-3 GDT070-3 GDT090-4 GDT115-5 GMTH045-3 GMTH070-4 GMTH090-5 GMTH115-5 GMNT040-3 GMNT060-3 GMNT080-4 GMNT100-4 GMNT120-5 GMPNO80-4 GMP100-3 GMP075-3 GMP0503 GMP050-3 GMP0754 GMP075-4 GMP100-3 GMP100-4 GDT115-5 GDT115-5A GMP100-5 GMP125-4 GMP125-5 GMP150-5 GMPN040-3 GMPN060-3 GMPN080-4 GMPN100-4 GMPN120-5 GMPV075 GMPV100 GMPV125 GMP 100-3 GPD050-3 GPD075-3 GPD100-4 GPD125-4 GMD050-3 GMD075-3 GMD100-4 GMD125-4 GMPE075-3 GMPE100-4 GMP100-3 GMP0753 GMPE125-5 GMPN100-4 GMN060-3 GMN080-4 GMN100-4 GMN120-4 9OGMT GMPOSO-3 GMPO5O-3 GMPN1205 GMNT
This Circuit Board Measures: 5-13/16" X 4-1/2.
Sorry, we do not accept personal checks at this time.
http://i138.photobucket.com/albums/q265/chrisauger/p681u.jpg
http://i138.photobucket.com/albums/q265/chrisauger/lgnd_rEN.jpg
We do not accept returns, exchanges or refunds on electrical items.
Please call or write for a return authorization number prior to returning product.
Items returned must be clean, in original packaging and re-sellable.
Special order items may not be returnable, please inquire when ordering items not listed as stock.
TO THE FULL EXTENT PERMISSIBLE BY APPLICABLE LAW, CLIMATE DOCTORS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. CLIMATE DOCTORS DOES NOT WARRANT THAT THIS SITE, ITS SERVERS, OR E-MAIL SENT FROM CLIMATE DOCTORS ARE FREE OF VIRUSES OR OTHER HARMFUL COMPONENTS. CLIMATE DOCTORS WILL NOT BE LIABLE FOR ANY DAMAGES OF ANY KIND ARISING FROM THE USE OF THIS SITE, INCLUDING, BUT NOT LIMITED TO DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, AND CONSEQUENTIAL DAMAGES.
SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES SO THESE LIMITATIONS MAY NOT APPLY TO YOU. THE WARRANTIES SET FORTH HEREIN GIVE YOU SPECIFIC LEGAL RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. IF A PRODUCT HAS BEEN PURCHASED FOR CONSUMER USE AS DEFINED BY 15 U.S.C. & 2301, ANY IMPLIED WARRANTY OR WARRANTIES SHALL EXPIRE ON EXPIRATION OF ANY EXPRESS WARRANTY.
We are the parts experts. We work closely with manufacturers to bring you a variety of quality items, at prices that help you get the job done within your budget. You don't have to go from store to store looking for what you need. You're certain to find great products, great value and great service at Climatedoctors.
We are here to answer your calls from 10 a.m. to 6 p.m. Eastern Time, Monday through Friday. Just call (***)-884-4420 or email us. We strive to get your email answered within 24 hours.
Contact: Shelly_Gilliam@rockford-industrial.com (Shelly Gilliam)




New ICM280 goodman furnace control circuit board hvac