The HydroStatâ„¢Model 3150 Universal
Temperature Limit and Low Water
Replaces Cold Start and Triple-Action Aquastats®*
• Install it on existing immersion well for full temperature functionality, or
• Install it on an Electro-WellTM to add low water cut-off protection
Simple dial-type temperature and differential settings.
Easy to wire - uses the same terminal designations as common Aquastat models.
Four on-board diagnostic indicating lights.
Saves time, materials and wiring.
*Aquastat is a registered tradmark of Honeywell International
The versatile new HydroStatâ„¢Model 3150
By installing the control on an existing immersion well, HydroStat can be used as a universal replacement for common Aquastat models. Whether it’s a cold start or a tankless coil boiler, HydroStat will provide all the temperature functions of the control being replaced.
Or, install HydroStat on a Hydrolevel Electro-WellTM (sold separately) to automatically activate the low water cut-off function. With HydroStat you can add low water cut-off protection to new or existing installations without the added time and cost to install a separate control.
Dial Type Temperature and Differential Settings
Allows for quick and easy adjustments.
This 3-digit LED display continually indicates boiler temperature. Whenever the high limit, low limit or differential temperature dials are turned, the LED instantly changes to display the setting temperature. For a quick reference, the LED will scroll through the current temperature and differential settings each time the HydroStat control is powered up.
HydroStat uses the same terminal designations as common Aquastat models. This makes field replacement
Four On-Board Diagnostic Indicating Lights
Indicates HydroStat is powered and the temperature function is active.
Illuminates any time the boiler is off on high temperature limit.
Only illuminates when the HydroStat is providing Low Water Cut-Off functionality. This function is activated by installing the control on a Hydrolevel Electro-Well. This LED will not illuminate when installed on a standard immersion well.
Indicates a low water condition in the boiler.
Click Here for Additional Information
To enable HydroStat's low water cut-off function, Electro-Wells are available in three sizes to replace standard immersion wells.
FOR ELECTRO-WELLS SEE HYDROLEVEL 48-202 OR HYDROLEVEL 48-201
Burner Contacts: 7.4 FLA, 44.4 LRA @120vac
Circulator Contacts: 5.8 FLA, 34.8 LRA @120vac
Operating Range – Low Limit: OFF or 110°F – 200°F
Operating Range – High Limit: 100°F – 220°F
Operating Range – Differential: 10°F – 30°F
Contact: bridgettmerritt@rockford-industrial.com (Bridgett Merritt)