Bodine B94 fluorescent emergency ballast 120/277


Bodine B94 fluorescent emergency ballast 120/277


From: Gena Alexander
Subject Bodine B94 fluorescent emergency ballast 120/277
BODINE B94 FLUORESCENT EMERGENCY BALLAST 120/277
Illumination Time - 90 Minutes
Initial Light Output - 300 - 750 Lumens
Dual Input Voltage - 120/277 VAC, 60 Hz
AC Input Power Rating - 4.0 Watts
Battery - High-Temperature,Maintenance-FreeNickel-Cadmium Battery 7- to 10-Year Life Expectancy
Battery Charging Current - 300 mA
Charging Indicator Light - LED
Temperature Rating (Ambient) - 0°C to +50°C (32°F to 122°F)
Dimensions - 9.4” x 2.4” x 1.5” (238 mm x 60 mm x 38 mm) 2’ (610 mm) Flex Conduit Each End Mounting Center 8.9” (226 mm)
When AC power fails, the B94 immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately 3 seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
The B94 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B94 may be installed on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 10 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C. For simple visual inspection of the charging indicator light and easy operational testing, the test/monitor plate can be installed near the fixture wall switch. It may also be installed in the ceiling near the fixture to ensure an unobtrusive installation.
The B9has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, “Emergency Lighting and Power Equipment,” and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA–LSC) and UL 90-minute requirements.